Check the IAT sensor with an ohms meter for resistance. The readings should be close to the following for reference. You can heat the sensor with a hair dryer to test the ranges.
Temperature/ Resistance
100 C (212 F) 2.07 K-ohms
90 C (194 F) 2.8 K-ohms
80 C (176 F) 3.8 K-ohms
70 C (158 F) 5.4 K-ohms
60 C (140 F) 7.7 K-ohms
50 C (122 F) 11 K-ohms
40 C (104 F) 16 K-ohms
30 C (86 F) 24 K-ohms
20 C (68 F) 37 K-ohms